{"id":64,"date":"2021-11-04T18:51:13","date_gmt":"2021-11-04T17:51:13","guid":{"rendered":"https:\/\/project.inria.fr\/retirex\/?page_id=64"},"modified":"2024-01-19T16:30:48","modified_gmt":"2024-01-19T15:30:48","slug":"presentation","status":"publish","type":"page","link":"https:\/\/project.inria.fr\/retirex\/","title":{"rendered":"Presentation"},"content":{"rendered":"<p><span class=\"fontstyle0\">There is a constant push to reduce both the radioactive dose injected into the patient and the duration<br>of a PET scan. Achieving these and providing real-time images require a new imager principle. 3-photon<br>gamma imaging is such a technique. Simulations of a small prototype, called XEMIS (Xenon Medical<br>Imaging System) showed the additional information helps localize the nuclear disintegrations.<br>Improvements are needed to scan a human body. In XEMIS, nuclear disintegrations necessitate two<br>data acquisition chains. One of them needs a new design to cater for a larger number of light detectors.<br>Determining which Events are in coincidence necessitates a specific hardware data processing ensure<br>Real-time imaging. Finally, new image reconstruction algorithms are required to take the third photon<br>into account. RETIREX aims at providing the key elements necessary to build the future whole-body 3-<br>photon imager.&nbsp;<\/span><\/p>\n<p>To address these, the RETIREX project is gathering 4 partners: IMT Atlantique (LabSTICC ARCAD and Subatech), LaTIM and UBS, each with the necessary skills to improve XEMIS, Fig1.<\/p>\n<p><a href=\"https:\/\/project.inria.fr\/retirex\/files\/2022\/01\/retirexproj.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone  wp-image-90\" src=\"https:\/\/project.inria.fr\/retirex\/files\/2022\/01\/retirexproj-300x133.jpg\" alt=\"\" width=\"704\" height=\"312\" srcset=\"https:\/\/project.inria.fr\/retirex\/files\/2022\/01\/retirexproj-300x133.jpg 300w, https:\/\/project.inria.fr\/retirex\/files\/2022\/01\/retirexproj-768x341.jpg 768w, https:\/\/project.inria.fr\/retirex\/files\/2022\/01\/retirexproj-1024x454.jpg 1024w, https:\/\/project.inria.fr\/retirex\/files\/2022\/01\/retirexproj-150x67.jpg 150w, https:\/\/project.inria.fr\/retirex\/files\/2022\/01\/retirexproj.jpg 1262w\" sizes=\"auto, (max-width: 704px) 100vw, 704px\" \/><\/a><\/p>\n\n\n<p>Fig. 1: Project&#8217;s workpackages and partners.<\/p>\n\n\n\n<p>A first XEMIS prototype, designed by Subatech, Fig .2,  is being assembled at Nantes&#8217; University Hospital, Fig 3.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><a href=\"https:\/\/project.inria.fr\/retirex\/files\/2024\/01\/XEMIS2-Design.jpg\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/project.inria.fr\/retirex\/files\/2024\/01\/XEMIS2-Design.jpg\" alt=\"\" class=\"wp-image-180\" width=\"550\" height=\"635\" srcset=\"https:\/\/project.inria.fr\/retirex\/files\/2024\/01\/XEMIS2-Design.jpg 733w, https:\/\/project.inria.fr\/retirex\/files\/2024\/01\/XEMIS2-Design-260x300.jpg 260w, https:\/\/project.inria.fr\/retirex\/files\/2024\/01\/XEMIS2-Design-130x150.jpg 130w\" sizes=\"auto, (max-width: 550px) 100vw, 550px\" \/><\/a><figcaption>Fig. 2: XEMIS2 prototype is designed to scan small animals.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/project.inria.fr\/retirex\/files\/2024\/01\/Camera-Xemis2.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"687\" height=\"370\" src=\"https:\/\/project.inria.fr\/retirex\/files\/2024\/01\/Camera-Xemis2.jpg\" alt=\"\" class=\"wp-image-178\" srcset=\"https:\/\/project.inria.fr\/retirex\/files\/2024\/01\/Camera-Xemis2.jpg 687w, https:\/\/project.inria.fr\/retirex\/files\/2024\/01\/Camera-Xemis2-300x162.jpg 300w, https:\/\/project.inria.fr\/retirex\/files\/2024\/01\/Camera-Xemis2-150x81.jpg 150w\" sizes=\"auto, (max-width: 687px) 100vw, 687px\" \/><\/a><figcaption>Fig. 2: XEMIS2 prototype being assembled at Nantes&#8217; University Hospital.<\/figcaption><\/figure>\n\n\n\n<p>Visit <a href=\"https:\/\/www.imt-atlantique.fr\/fr\/recherche-innovation\/collaborer\/projet\/xemis-2\">Xemis 2 | IMT Atlantique (imt-atlantique.fr)<\/a> for more information about XEMIS2.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>There is a constant push to reduce both the radioactive dose injected into the patient and the durationof a PET scan. Achieving these and providing\u2026<\/p>\n<p> <a class=\"continue-reading-link\" href=\"https:\/\/project.inria.fr\/retirex\/\"><span>Continue reading<\/span><i class=\"crycon-right-dir\"><\/i><\/a> <\/p>\n","protected":false},"author":1754,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-64","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/project.inria.fr\/retirex\/wp-json\/wp\/v2\/pages\/64","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/project.inria.fr\/retirex\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/project.inria.fr\/retirex\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/project.inria.fr\/retirex\/wp-json\/wp\/v2\/users\/1754"}],"replies":[{"embeddable":true,"href":"https:\/\/project.inria.fr\/retirex\/wp-json\/wp\/v2\/comments?post=64"}],"version-history":[{"count":7,"href":"https:\/\/project.inria.fr\/retirex\/wp-json\/wp\/v2\/pages\/64\/revisions"}],"predecessor-version":[{"id":183,"href":"https:\/\/project.inria.fr\/retirex\/wp-json\/wp\/v2\/pages\/64\/revisions\/183"}],"wp:attachment":[{"href":"https:\/\/project.inria.fr\/retirex\/wp-json\/wp\/v2\/media?parent=64"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}